Amraiwadi, Ahmedabad, Gujarat
GST No. 24ALEPP6869R1Z3
Call 08046040193 89% Response Rate
Minimum Order Quantity: 1 Piece
Product Brochure
Application Media | Water |
Brand | Achievers |
Line Size | 004 mm to 150 mm |
Model | CE-210 |
Flow range | 5 - 500 Litre / Min |
Accuracy | 0.5 % |
Digital Communication | RS - 485 Modbus or 4-20 ma |
Usage | Use 100 mesh strainers |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Accuracy | +/-1% |
Display | Digital |
Brand | Achievers |
Pressure Loss | 0~1000 mpas |
Working Pressure | 1.6-42 MPa |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Application Media | OIL |
Usage/Application | INDUSTRIES |
Brand | Achievers |
Line Size | 1-3 inch |
Model Name/Number | CE 111 |
Material | Aluminum,ms |
Voltage | 12/24 V |
Repeatability | +/-0.50% |
Maximum Capacity | +/-0.5%, 201 at maximum capacity +/-1% |
Additional Information:
View Complete details
Product Brochure
Application Media | Oil |
Brand | Achievers |
Min Flow | 120-300 LPM |
Repeatability | 0.03% |
Max Viscosity | 1000 CPS |
Max Pressure | 3.41-81.8 Mpa |
Accuracy | 0.50% |
Size | 25-50 mm |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model | CE-110-40 |
Brand | Achievers |
Repeatability | Less than 0.03% |
Max Working Pressure | 1.8 Mpa |
Max Viscosity | 1000 CPS |
Inlet and Outlet | 40 mm / 1.5'' |
Flow range | 25-250 lpm |
Accuracy | +/-0.5% |
CE-111 Achievers Developed Digital Positive Displacement Flow Meter is a superior choice for flow measurement of very wide range of viscosity fluids with the help of Positive Displacement Technology. With the latest technology this flow meter is a very good choice for fluids with wide rage of viscosities. Achievers Flow Meters provides great accuracy and repeatability over the full range of measurement. This flow sensor is considered the best choice for diesel, oil, fuel and wide range of other fluids. Please consult an achievers associate for more help.
Features:
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Achievers |
Line Size | 004 mm - 150 mm |
Max Working Pressure | 3.4 Mpa |
Operating Temperature (Celsius) | 0-135 |
Flow range(Min-Max) | 0 - 1500 Litre/Min |
Accuracy | 0.2 % - 0.5 % |
We are a trader of a wide range of Biodiesel Flow Meter. This Diesel Flow Meter is compact design, high performance, reliability, accuracy, up to 0.5% accuracy comes with field calibration facility. Applicable in the automobile industry, this offered Diesel Flow Meter is made available in various specifications as per the needs of the clients.Now Get Best Diesel flow meters from us.
Specifications of Biodiesel Flow Meter:
Features of Biodiesel Flow Meter:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Process Temperature | 150 C max |
Process Pressure | 30 kg/cm3 max |
Repeatability | - 1% |
Linearity | - 1% |
Material of Construction | Body, Bearing, Support & Flange - SS 316 / Teflon |
Display | 8 x 1 LCD/ 4x1 LED, 8 x 1 LED |
Application Media | Liquids (Clear) |
Brand | Achievers |
Line Size | 15 NB to 150 NB |
Accuracy | - 1% F. S |
Technical Specifications of flow meters:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Fluid and Ambient Temperature | -40 to 150 deg C |
Brand | Achievers |
Material | Cast Iron or Stainless Steel |
Flow range | 0 - 1700 Litre / Min |
Voltage | 3-24 V DC |
Power Voltage | 12 V DC or 24 V DC or 220 V AC |
Achievers precision digital oval gear positive displacement flow meter available with RS485/Pulse/Current/Hart output and inbuild flowrate and totalize digital display positive displacement flow measurement with two oval shape gear, Gear rotate when flow pass on measuring chamber and Magnetic pickup sensor/ Hall sensor used for measuring the rotation of the gear, and each rotation equal to fix the value of fluid qty,
Maximum working pressure:
Material of Construction:
Product Features:
Range oval gear flow meter application selection as per bellow detail:
Product Applications:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Accuracy | +/-1% |
Display | Digital |
Brand | Achievers |
Material | Aluminum |
Flow Meter | Oval gear flow meter |
Diameter | 1/2" |
Application | Gas, Diesel, Kerosene etc |
Oval Gear Flow Meter is a kind of positive displacement oil flow meter to measure the liquid flow or instantaneous flow of the pipe tube. It is a kind of accumulate meter. With characteristics of high accuracy, small change by the fluid viscosity, it is widely used to measure oil kind liquid, but it is forbidden to measure corrosive liquid.get best oil flow meter deal from us.
View Complete details
Product Brochure
Material | Stainless Steel |
Brand | Achievers |
Usage/Application | Automotive |
Display Type | digital |
Flow Range | standard |
Line Size | standard |
Ambient Temp | standard |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Achievers |
Accuracy | +/- 1% |
Measurement | Litre / Gallon |
Materials | Aluminium, Viton Seal, Veeder-Root |
Max Pressure | 10 bar / 150 psi |
Repeatability | More than or Equal to 0. 05% |
High Accuracy Diesel Flow Meter uses positive displacement method to measure flow of liquid upto the accuracy of 0.2%. High Accuracy Diesel Flow Meter designed by CHINTAN ENGINEERS is a smart meter that has the capability to measure diesel upto the highest accuracy. High Accuracy Diesel Flow Meter are available in a wide range of size with wide flow ranges. CHINTAN ENGINEERS manufactures these High Accuracy Diesel Flow Meter with utmost care and with modern technologies.
Features of High Accuracy Diesel Flow Meter:
Model | CE-PDFM-40 | CE-PDFM-50 | CE-PDFM-80 | CE-PDFM-100 |
Size | 40mm or 1 ½” | 50mm or 2” | 80mm or 3” | 100mm or 4” |
Flow range | 25-250 l/min. | 38-380 l/min. | 75-750 l/min. | 130-1300 l/min. |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Operating Temperature | 0-140 deg C |
Accuracy | 0.2 - 0.5 % |
Flow range | 0-2000 L/Min |
Operating Pressure | 3.2 Mpa |
Line Size | 6 mm - 150 mm |
Connectivity | RS485 |
Brand | Achievers |
“Achievers” make versatile digital flow meter is ideal for conductive liquids such as Raw Water, Chilled water, effluents, Potable water etc. Using time proven electromagnetic flow metering principle, the meter achieves a flow meter for pipes from 15mm to 600mm. Since there are no moving parts, the flow meter gives years of maintenance free service.
“Achievers” flow-head can be supplied in Teflon lining or Hard Rubber lining is available with all the features required in a field mounted water metering equipments. These include - weather proof enclosure, communication options, RTC with data logging with printer option and 4 to 20 mA isolated Flow signal transmission option for flow pattern recording. The converter is available as field mounted-IP65 protection category. GSM modem interface can also be supplied as an optional add-on feature.
The operating principle of Magnetic flow meters is based upon Faraday's Law of electromagnetic induction, “It state that a voltage will be induced in a conductor moving through a magnetic field”.ocity of the conductor
The magnitude of the induced voltage E is directly proportional to the velocity of the conductor width D, and the strength of the magnetic field B. Liquid acts as a conductor as it flows through pipes. This Flowmeters find varied applications where the flowing medium is difficult to handle.
Major advantage of these flowmeters are:
Some of the major application can be described below:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | CE-112-100 |
Connection Size | 4'' Thread |
Maximum Working Pressure | 10 Mpa (35~85% Rh) |
Fluid and Ambient Temperature | - 40 to 80 deg C |
Power Voltage | -5/24 V DC |
Output High Electric Level | Less than 4.5 V DC (Input Voltage 5 V DC) |
Output Low Electric Level | Higher Than 0.5 V DC (Input Voltage 5 V DC) |
Connection | Thread (M/F) or Flange |
Series | CE-112 |
Factor | 1.0 L/P(1/K) |
Brand | Achievers |
Accuracy | + 1% Rs / /0.25% FSD(Standard Installation Position) |
Flow Range | 2,000~100,000 L/H |
Model & Size | Connection Size | Flow Range | 1/K-FACTOR (L/P) |
CE-112-004 | 1/4" Thread | 0.2 ~ 60 L/H | 0.000416 L/P |
CE-112-006 | 1/4” Thread | 5~150 L/H | 0.000661 L/P |
CE-112-008 | 3/8” Thread | 20~300 L/H | 0.0025 L/P |
CE-112-010 | 1/2” Thread | 50~800 L/H | 0.0025 L/P |
CE-112-015 | 1/2” Thread | 80~1,500 L/H | 0.0085 L/P |
CE-112-020 | 3/4” Thread | 150~2,000 L/H | 0.0154 L/P |
CE-112-025 | 1” Thread | 200~4,000 L/H | 0.0256 L/P |
CE-112-040 | 1.5” Thread | 500~10,000 L/H | 0.086 L/P |
CE-112-050 | 2” Thread | 600~20,000 L/H | 0.19 L/P |
CE-112-080 | 3” Thread | 1,000~50,000 L/H | 0.54 L/P |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | CE-50 |
Accuracy | +/-1% |
Size | 2" |
Max Viscosity | 1000 CPS |
Max Operating Pressure | 1.8 MPa |
Min Flow Rate | 30 L/min |
Max Flow Rate | 300 L/min |
Repeatability | 0.03% |
Model | CE-25 | CE-40 |
Size | 1" | 1.5" |
Min.Flow Rate | 20 L/min | 25 L/min |
Max.Flow Rate | 200 L/min | 250 L/min |
Accuracy Model | ±0.5% | ±0.5% |
Repeatability | 0.03% | 0.03% |
Max.Viscosity | 1000 CPS | 1000 CPS |
Max.Operating Pressure | 3.4 MPa | 1.8 MPa |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Application Media | Diesel, Gasoline, Kerosene |
Brand | Achievers |
Max Value of the Zeroing | 999.9 |
Viscosity | 8-5000 mPas |
Totalizator | 99999999 |
Accuracy | +/- 0.5% |
Operating Pressures | Up to 50 psi / 3.5 bar |
To match up the varying demands of the clients, we are engaged in offering extensive array of Diesel Flow Meter. Our provided Diesel Flow Meter is rigorously tested by the team of quality controllers to ensure its reliable performance. Our prestigious clients can avail our entire products range from us at market leading prices.These flowmeter are reliable, inexpensive, easy to install and simple to calibrate on the workplace. Ithas the advantage of large number range, easy to read, quick reset knob, horizontally and verticallyflexibility of installation option.
Features of diesel flow meter:
Specifications of diesel flow meter:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model | CE-110-25 |
Brand | Achievers |
Accuracy | +/-1% |
Flow range | 20-120 lpm |
Max Viscosity | 1000 CPS |
Inlet and Outlet | 25 mm / 1'' |
Repeatability | Less than 0.03% |
Max Working Pressure | 3.4 Mpa |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | CE-210-020 |
Maximum Working Pressure | 2.5 Mpa |
Output Signal | 4 to 20 mA |
Connection | Thread (M) |
Power Voltage | 24 V DC |
Fluid and Ambient Temperature | -40 to 120 deg C |
Pulse Per Litre | 52 |
Line Size | 1.25'' BSP |
Brand | Achievers |
Accuracy | +/- 0.5 or 1% FSD (standard installation position) |
Flow Range | 80-800-8000 L/H 97 |
Repeatability | 0.05% |
CE-210 Achievers Developed Helical Flow Meter is a superior choice for flow measurement of very high viscosity fluids with the help of Positive Displacement Technology. With the latest technology of K-factor this flow sensor is a very good choice for fluids with changing flow rates. Achievers Flow Sensor provides great accuracy and repeatability over the full range of measurement. This flow sensor is considered the best choice for measurement in laminating systems, painting systems, adhesive dispense systems, as well as batching systems for various fluids.
Features:
Material Of Construction:
Specifications:
Model | Line Size | Flow Range(Litre/Hour) |
CE-210-004 | 1/4'BSP | 5-40-400 L/H 4200 |
CE-210-008 | 1/2' BSP | 10-150-1500 L/H 1200 |
CE-210-012 | 3/4' BSP | 50-500-5000 L/H 215 |
Applications:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Fluid and Ambient Temperature | -40 to 80 C |
Power Voltage | 5 - 24 V DC |
Brand | Achievers |
Maximum Working Pressure | 10MPa (35~85%RH) |
View Complete details
Minimum Order Quantity: 1 Piece
Brand | Achievers |
Flow range | 0 - 1700 Litre / Hour |
Display | Digital |
Connectivity | RS485 |
Line Size | 004 mm to 150 mm |
Material | SS and PP |
Accuracy | 0.2 % - 0.5 % |
View Complete details
Minimum Order Quantity: 1 Piece
Connection | Thread (M/F) or flange |
Viscosity Range | -0.612-5.35 mm2/s |
Fluid and Ambient Temperature | -40 to 80 deg C |
Output Low Electric Level | Higher than 0.5 V DC( input voltage 5 VDC) |
Maximum Working Pressure | 10 MPa (35~85%RH) |
Power Voltage | 5 - 24 V DC |
Output Signal | NPN |
Output High Electric Level | Less than 4.5 V DC( input voltage 5 V DC) |
Brand | Achievers |
We are viewed as one of the highest brand offering a wide collection of Achievers Make Adblue Flow Meter that depends on the time tried Oscillating Piston outline. A solitary moving segment in the get together guarantees to a great degree solid operation for a long stretch of operation. Utilization of best in class strong state attractive sensor, ultra low fueled electronic sensor accommodates all the effortlessness of a mechanical Adblue Flow measurement and the unwavering quality of electronic detecting and reads outs. Our digital adblue flow meter is created utilizing quality crude material obtained from solid sources. We offer best products at truly moderate costs. Also Know as: Print Flow Meter With Ticket Printer, High Accuracy ADBLUE Flow Meter, Flange Type Adblue Flow Meter.
Features:
Applications:
Material of Construction:
View Complete details
Minimum Order Quantity: 1 Unit
Brand | Achievers |
Flow Rate | 0-999.99 (DP Autoshift) |
Panel Cutout | 92x92 mm |
Display | 128x64 Bit Graphical LCD |
Power Supply | 9 V to 36 V DC |
Accuracy | 1% of FSD |
Total Flow Range | 0-99999.99 |
Size | 96Hx96Wx55D mm |
We are leading suppliers and manufacturers of Truck Diesel Engine Flow Meter. Available with us at industry leading prices, these products are highly demanded for their optimum performance and low maintenance. To ensure high standards of quality, the raw materials used in the manufacturing of the offered products are procured from trusted and reliable vendors of the industry.
Features:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Material | aluminum |
Usage/Application | industrial |
Application Media | Diesel |
Model | CE-111-50 |
Brand | Achievers |
Model Name/Number | 111 |
Color | Blue |
Display | Digital |
Packaging Type | thermocol and corrugated box |
Power Supply | 3 v dc |
Accuracy | +/- 0.5 % |
Flow range | 30-300 lpm |
Power Consumption | 3 v |
Repeatability | Less than 0.03% |
Max Working Pressure | 1.8 Mpa |
Max viscosity | 1000 CPS |
Inlet and Outlet | 50mm / 2'' |
Country of Origin | Made in India |
Model | CE-111-25 | CE-111-40 |
Inlet and Outlet | 25mm / 1” | 40mm / 1.5” |
Flow range | 20-120lpm | 25-250lpm |
Accuracy | 0.50% | 0.50% |
Repeatability | <0.03% | <0.03% |
Max working pressure | 3.4Mpa | 1.8Mpa |
Max viscosity | 1000CPS | 1000CPS |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Achievers |
Line Size | 1" - 6" |
Model | CE-113 |
Flow range | 12 - 400 LPM |
Operating Pressure | 10 Bar |
Operating Temperature | 20-140 |
Accuracy | 0.2 % - 0.5 % |
Repeatability | 0.05 % |
Model | 113-40-1 | 113-50-1 | 113-80-1 | 113-100-1 | 113-150-1 |
Line Size | 1 ½” | 2” | 3” | 4” | 6” |
Flow Rate | 25-250 L/Min | 55-550 L/Min | 115-1150 L/Min | 170-1700 L/Min | 300-3000 L/Min |
Strainer Type | 80 Mesh For Diesel | 40 Mesh For Gasoline |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Display | Analog |
Model | CE-104 |
Brand | Achievers |
Flow Rate | 0 to 120 L/min |
Meter Accuracy | + -1% |
Accumulated Counting Digit | 8 Digit |
Medium | Diesel,Kerosene,Gasolene |
Intel Size | 1" |
View Complete details
Product Brochure
Brand | Achievers |
Flow Range | 0 - 1700 Litre / Min |
Material | Cast Iron or Stainless Steel |
Voltage | 3-24 V DC |
Power Voltage | 12 V DC or 24 V DC or 220 V AC |
Fluid and Ambient Temperature | -40 to 150 deg C |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Achievers |
Flow range | 160~1600 L/min |
Accuracy | +/- 1% |
Size | 4'' or 100 mm |
Repeatability | +/-0.03% |
Operating Pressure | 1.8 Mpa |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Display | Remote, Local |
Flow range(min-Max) | 0 - 1500 Litre/Min |
Automation Grade | Automatic |
Connectivity | 4-20 ma, RS485 |
Line Size | 4 mm to 150 mm, 1/2" inch to 6" Inch |
Accuracy (%) | 0.2 - 1 % |
Color | Black |
Usage/Application | Any non corrosive liquid |
Accuracy | 0.2 % - 1 % |
Brand | Achievers |
Model | CE-110 |
To match up the varying demands of the clients, we are engaged in offering extensive array of Liquid Flow Meter. Our provided Liquid Flow Meter is rigorously tested by the team of quality controllers to ensure its reliable performance. Our prestigious clients can avail our entire products range from us at market leading prices.
Features of Liquid Flow Meters:
Specifications of Liquid Flow Meters:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Achievers |
Display | Digital |
Packaging Type | Aluminum Box |
Transducers | Available for 10 to 5000 mm pipe dia |
Wide Operating Temperature Range | -40 deg C to 250 deg C |
We are leading manufacturer and supplier of Ultrasonic Flow Meter Kit. Ultrasonic Flow Meter Kit have been used in industry for over a long period of time for the volumetric flow metering of liquids as well as gasses. This method has been working successfully in industrial applications for more than 20 years. It is accurate and reliable. Besides measuring the volumetric flow rate, the method provides information on the type of liquid product based on the sound velocity that is measured in parallel. Ultrasonic flow measurement by the transit-time differential method is now one of the most universally applied flow metering processes to employ clamp on, non intrusive method in closed conduit and intrusive method by inserting probes on pipe. Open channel flow measurement is also done by ultrasonic transit time technique. The latest innovation of low-cost handheld Ultrasonic Flow Meter is one of the most useful flow meters available for liquid flow measurement. It employs state-of-the-art digital signal processing and clamp-on ultrasonic transit-time measurement technologies for accurate and reliable flow measurement non-intrusively from outside of a pipe. In this compact and light package, many built-in features make the flow meter an ideal tool for flow surveys (water, oil, chemicals, beverage, etc), HVAC and other closed-pipe applications.
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | Achievers |
Material | Mild Steel |
Flow range(Min-Max) | 0-1700 Litre/Min |
Operating Pressure | 3.2 Mpa |
Line Size | 6-150 mm |
Connectivity | RS485 |
Accuracy (Percentage) | 0.5 - 1 % |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | CE-210-25 |
Color | Red and White |
Connection | Thread (M) |
Pulse Per Litre | 52 |
Output Signal | 4 to 20 mA |
Power Voltage | 24 V DC |
Maximum Working Pressure | 2.5 Mpa |
Fluid and Ambient Temperature | -40 to 120 deg. C |
Flow range | 100-1000-10000 L/H |
Line Size | 1.25'' BSP |
Brand | Achievers |
Accuracy | +/- 0.5 Or 1% FSD(Standard Installation Position) |
Repeatability | 0.05% |
Model | Line Size | Flow Range(Litre/Hour) |
CE-210-004 | 1/4''BSP | 5-40-400 L/H 4200 |
CE-210-008 | 1/2'' BSP | 10-150-1500 L/H 1200 |
CE-210-012 | 3/4'' BSP | 50-500-5000 L/H 215 |
CE-210-020 | 1.25'' BSP | 80-800-8000 L/H 97 |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Unit
Product Brochure
Brand | Achievers |
Flow range | 1,000~50,000 L/H |
Model Name/Number | CE-112-080 |
Output Low Electric Level | Higher than 0.5 V DC (Input Voltage 5 V DC) |
Fluid and Ambient Temperature | - 40 to 80 deg C |
Output High Electric Level | Less than 4.5 V DC (Input Voltage 5 V DC) |
Connection Size | 3'' Thread |
Factor | 0.54 L/P(1/K-) |
Maximum Working Pressure | 10 Mpa (35~85% Rh) |
Power Voltage | -5/24 V DC |
Accuracy | + 1% Rs / /0.25% FSD (Standard Installation Position) |
Model & Size | Connection Size | Flow Range | 1/K-FACTOR (L/P) |
CE-112-004 | 1/4" Thread | 0.2 ~ 60 L/H | 0.000416 L/P |
CE-112-006 | 1/4” Thread | 5~150 L/H | 0.000661 L/P |
CE-112-008 | 3/8” Thread | 20~300 L/H | 0.0025 L/P |
CE-112-010 | 1/2” Thread | 50~800 L/H | 0.0025 L/P |
CE-112-015 | 1/2” Thread | 80~1,500 L/H | 0.0085 L/P |
CE-112-020 | 3/4” Thread | 150~2,000 L/H | 0.0154 L/P |
CE-112-025 | 1” Thread | 200~4,000 L/H | 0.0256 L/P |
CE-112-040 | 1.5” Thread | 500~10,000 L/H | 0.086 L/P |
CE-112-050 | 2” Thread | 600~20,000 L/H | 0.19 L/P |
View Complete details
Minimum Order Quantity: 1 Piece
Flow Range | 0-1500 m3/hr |
Material | Stainless Steel and Cast Iron |
Display | Digital |
Brand | Achievers |
Accuracy | 1 % |
Types | Clamp on,Flange End |
Compressed Air Flow Meters generally uses more electricity than any other type of equipment, and accounts for as much as a third of the energy usage in an industrial facility. Achievers Air Flow Meters help identify leaks in compressor systems, track overall usage to improve plant efficiency, and help departments reduce consumption. This can save huge money each month in large industrial applications. For instance, the compressed air flow meter can be used with energy management systems to help determine the optimal number of compressor units that need to be in operation at any given time, this helps to meet the demand of various departments and processes. Furthermore, Compressed air flow meters are sensitive enough to determine leaks.
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | CE-144 |
Brand | Achievers |
Accuracy | +/- 0.5 Or 1% (Standard Installation Position) |
Power Voltage | 12 V DC |
Repeatability | 1% |
Maximum Working Pressure | 6 Mpa |
Fluid and Ambient Temperature | -20 to 120 deg C |
We have come up with reliable turbine flow meters. The turbine flow meters that we offer are manufactured with impart strength and endurance. Our turbine flow meters provide accurate readings of the flow with an absolute sophisticated and work with utmost precision. The RS485 communications standard is used by measurement systems sensor based data acquisition modules and many industrial control devices.
Principle of operation turbine flow meters:
View Complete details
Product Brochure
Brand | Achievers |
Flow range | 80-800-8000 L/H |
Model Name/Number | CE-210-012 |
Material | Achievers |
Pulse Per Litre | 97 |
Maximum Working Pressure | 2.5 Mpa |
Fluid and Ambient Temperature | -40 to 120 deg C |
Output Signal | 4 to 20 mA |
Power Voltage | 24 V DC |
Line Size | 1'' BSP |
Connection | Thread (M) |
Accuracy | +/- 0.5 or 1% FSD (standard installation position) |
Repeatability | 0.05% |
View Complete details
Minimum Order Quantity: 1 Piece
Brand | Achievers |
Flow range | 2000 Litre/Min |
Power Supply | 4-20 mA DC |
Connectivity | RS485 |
Line Size | 4 mm to 150 mm |
Accuracy | 0.2 % - 0.5 % |
View Complete details
Minimum Order Quantity: 1 Piece
Brand | Achievers |
Display | 2 line LCD display |
Power Supply | 24 V DC or 85-264 V AC |
input | 4-20 mA/PT100 |
Repeatability | 1% |
Output | Relay/OCT/RS485/4-20 mA/0-20 mA |
Specifications:
View Complete details
Minimum Order Quantity: 1 Piece
Brand | Achievers |
Accuracy | Normally better than +/-1% for velocity above 0.2m/s |
Response Time | 0-999 seconds,user-configurable |
Velocity | +/-0.01 ~ +/-32 m/s,bi-directional |
Pipe Range | DN200 mm~DN6000 mm |
Linearity | Better than 1% |
Repeatability | 0.2% |
Specifications:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Material | aluminum |
Application Media | diesel/oil |
Usage/Application | industrial |
Display | Digital |
Flow range | 0 - 2000 L / Min |
Brand | Achievers |
Model Name/Number | CE-111/119 |
Line Size | 004 mm to 150 mm |
Accuracy | 0.2 % - 0.5 % |
Operating Pressure | 10 KG/CM2 |
Operating Temperature Range | 80 DEGREE |
Owing to our rich experience and vast knowledge of this domain, we have been able to offer high quality Electronic Flow Meter to our valuable customers. Known for their rich features such as longer operational life and perfect finish and durability, the offered meters are highly demanded. Offered by us at industry leading prices, these products are highly appreciated in the market.
Being the foremost names in the industry, we are offering an extensive range of Digital Oil Flow Meter that is a kind of accumulate meter or positive displacement meter. Our industry-experts design this flow meter by making use of quality proven material and modern machines. Acknowledged for its compact size, light weight and precision-designed, this flow meter is used to measure the liquid flow or instantaneous flow of the pipe tube.
Features:
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | CE-110-50 |
Brand | Achievers |
Accuracy | 1% |
Flow Range | 30-300 lpm |
Repeatability | More than 0.03% |
Inlet and Outlet | 50 mm / 2'' |
Max Working Pressure | 1.8 Mpa |
Max Viscosity | 1000 CPS |
Specifications:
Model | CE-110-25 | CE-110-40 | CE-110-50 |
Inlet and Outlet | 25mm / 1” | 40mm / 1.5” | 50mm / 2” |
Flow range | 20-120lpm | 25-250lpm | 30-300lpm |
Accuracy | 0.005 | 0.005 | 0.005 |
Repeatability | <0.03% | <0.03% | <0.03% |
Max working pressure | 3.4Mpa | 1.8Mpa | 1.8Mpa |
Max viscosity | 1000CPS | 1000CPS | 1000CPS |
View Complete details
Minimum Order Quantity: 1 Piece
Brand | Achievers |
Display | Digital |
Flow range | 1-600 LPM |
Connectivity | RS485 |
Line Size | 004 mm to 150 mm |
Accuracy | 1% |